Explosion-proof structure and intelligent control system of 300 m³ natural gas refrigerated dryer
Custom Design Highlights of Natural Gas Chillers (Refrigerated Dryers) for Class II Industrial and Mining Oil and Gas Wells
In response to the Class II explosion-proof industrial and mining environment of oil and gas wells in the mountainous areas of Sichuan, our company has introduced natural gas chillers with a processing capacity of 1000–5000 Nm³/d, also commonly known as natural gas refrigerated dryers or natural gas low-temperature drying units. The equipment is strictly tailored to the harsh working conditions of open-air oil wells in the field, with comprehensive customized optimization in explosion-proof safety, anti-icing, seasonal energy saving, field protection, lifting structure, and intelligent monitoring. The core design highlights are explained one by one below. I. Whole-unit explosion-proof design: strictly complying with explosion-proof regulations for Class II areas. Explosion protection is the first design bottom line for natural gas processing equipment, and the entire electrical system strictly follows explosion-proof standards: the explosion-proof control cabinet body structure strictly controls the thickness of the cabinet shell plates, and the cabinet reinforcing ribs strictly meet standards, eliminating the risk of explosion-proof failure caused by insufficient shell strength. All wiring terminals uniformly use explosion-proof dedicated terminals, eliminating the hidden danger of arcs from ordinary terminals. All cable entries and exits are sealed with explosion-proof cable glands, and the use of PTFE tape as a substitute for sealing components is strictly prohibited. PTFE tape sealing cannot meet explosion-proof airtightness requirements and can easily cause explosive gas to seep into the cabinet, which is also a practice explicitly prohibited in the explosion-proof industry. Electrical accessories must have 3C explosion-proof qualification. The compressor-matched explosion-proof heat tracing cable and heat tracing junction box all use explosion-proof components with complete 3C certification. To avoid non-professional personnel opening the cover for operation, after factory commissioning and qualification, the control cabinet is designed to minimize unnecessary cover-opening structures. Once opened at will, combustible mixed gases in the field environment can easily intrude into the enclosure and cause safety accidents. All operation buttons on the whole unit are explosion-proof type, and an independent emergency stop button is configured to avoid on-site misoperation risks. Electrical control partition layout facilitates inspection and maintenance.
The fan control contactors are arranged in an independent partition, using first-tier brand components. The control cabinet is provided with a double-layer protection structure, separating an independent maintenance compartment, with clear line partitions, making later troubleshooting and component replacement more convenient. Explosion-proof terminals and main cables are arranged in separate zones, further improving electrical explosion-proof stability.
II. Refrigeration system optimization: preventing low-temperature evaporation icing. The core refrigeration component of the unit is the compressor package. Under natural gas low-temperature processing conditions, an excessively low evaporation temperature can easily cause pipeline icing and blockage. During the design stage, the unit operating load is accurately calculated, and an explosion-proof heat tracing cable is additionally installed, relying on temperature-linked control to suppress icing and ensure continuous uninterrupted operation. III. Seasonal variable-frequency fan control: achieving high efficiency and energy saving specifically for Sichuan oil and gas wells. Oil and gas wells in the mountainous areas of Sichuan have extremely large day-night temperature differences. In winter, the wellsite ambient temperature can drop to 0–5°C, while in summer there is long-term high-temperature exposure. For this reason, we abandoned traditional differential pressure switches and selected high-precision pressure transmitters as the core sensing elements to achieve grouped start-stop control of condensing fans: In high-temperature summer conditions: both condensing fans run at full speed simultaneously to ensure sufficient air volume and air pressure, meet the unit's heat dissipation requirements, and avoid high-temperature and high-pressure shutdown of the unit; In low-temperature winter conditions: only one fan is started to maintain condensing temperature, while the other automatically stands by, greatly reducing no-load energy consumption.
This dual-fan grouped control scheme is an energy-saving design tailored to the climate of oil wells in the mountainous areas of Sichuan. On the premise of ensuring stable refrigeration dew point, it significantly reduces the electricity cost of long-term field equipment operation. IV. Field industrial and mining protection structure, adapted to mountainous open-air environments. Oil and gas wells are mostly located in mountain forests and fields, where fallen leaves and weeds can easily block the heat dissipation surface. The unit is shipped with a closed safety protection mesh as standard, with mesh openings designed strictly according to safety standards so that fingers cannot reach in. It can block dead branches and weeds from being drawn into the fan and also facilitates regular cleaning of debris, eliminating unit overheating caused by blocked heat dissipation surfaces. In terms of the air inlet and outlet structure, the equipment inlet and outlet adopt a parallel horizontal arrangement instead of a vertical top-bottom structure, preventing debris from falling into the cylinder during on-site installation and reducing later pipeline blockage faults. The pre-filter is equipped with a dual-path parallel structure of automatic blowdown + manual blowdown, with a customized valve for centralized blowdown to ensure intake cleanliness; at the same time, multi-stage protection including gas seal and oil seal is fully provided, fully adapting to impurity-containing raw natural gas in mountainous areas and stably accommodating an intake processing capacity of 1000–5000 cubic meters per day. V. Strengthened enclosure structure to solve mountainous lifting difficulties. The whole unit is an integrated skid-mounted enclosure structure. Field oil wells mostly rely on truck-mounted cranes and overhead cranes for equipment transfer. Dedicated lifting lugs are welded on the top of the enclosure; only lifting operations are permitted, and forklift clamping from both sides for handling is prohibited. Forklift clamping creates local stress angles and can easily cause extrusion deformation of the enclosure plates. The lug structure perfectly matches oilfield on-site lifting conditions, ensuring that the enclosure does not deform and pipelines do not tear during equipment transfer. The unit is equipped with well-known brand motors and imported 4K-grade bearings, adapting to continuous uninterrupted field operation and improving the service life of the whole unit. VI. Multi-dimensional temperature monitoring + IoT remote control. The equipment is equipped with a multi-point temperature monitoring module to collect natural gas inlet temperature and gas outlet temperature in real time; at the same time, thermal resistors are installed inside the explosion-proof control cabinet to continuously monitor the ambient temperature inside the cabinet. Open-air exposure in the field can easily cause excessive temperature rise of electrical components in the cabinet, and real-time temperature control can predict hidden dangers of electrical aging in advance. The whole unit is equipped with an IoT touch screen. After customer authorization, the backend can remotely collect all operating data, focusing on monitoring control cabinet temperature, unit start-stop, and refrigeration conditions, achieving unattended remote operation and maintenance, making the operating data of oil and gas extraction equipment fully controllable throughout the process and ensuring long-term safe production. Summary: This natural gas chiller is tailor-made for Class II explosion-proof oil and gas wells in the mountainous areas of Sichuan, putting explosion-proof safety first and balancing six core requirements: winter anti-freezing, summer heat dissipation, fan energy saving, field anti-blocking, skid-mounted lifting, and online remote monitoring. It strictly avoids illegal explosion-proof construction operations and optimizes all links from mechanical structure, electrical explosion protection, and intelligent monitoring. It is a dedicated refrigerated dryer for natural gas dehydration and drying in small and medium gas volume oil and gas wells.