It can operate stably. This unit adopts mechanical compression refrigeration and does not rely on the pressure energy of the gas itself (different from the J-T throttling process). It is specially designed for 0.2-0.3MPa low-pressure oilfield associated gas. As long as the inlet gas volume and temperature are within the design range, the refrigeration unit can stably cool natural gas to ≤-10℃; the front-end molecular sieve ensures the outlet gas dew point is ≤-60℃, avoiding hydrate freezing and blockage in the low-temperature system; design parameters reserve margin, and under conditions of slight pressure fluctuation the equipment can still stably produce qualified dry gas and recover mixed hydrocarbons.
"Zero emission" means no finished natural gas is vented or released to the atmosphere; it does not mean completely zero gas consumption. The regeneration process draws a small amount of dried finished gas from within the system as regeneration gas, which is pressurized and heated to desorb the molecular sieve. The regeneration gas carrying water vapor is cooled to separate liquid water, and then all the gas is returned to the internal process system for circulation without venting to the atmosphere. There will be extremely small normal system leakage losses, but there is no large amount of direct natural gas emission, greatly reducing gas loss and VOCs environmental risks.
Under the premise of qualified gas quality and normal maintenance of the pretreatment filter, the designed service life of the molecular sieve is 3-5 years. The adsorption tower is specially equipped with dedicated molecular sieve loading and unloading ports, allowing filling and unloading without disassembling the main process pipelines; combined with a flat-spread diffusion inlet structure, it reduces airflow impact and molecular sieve pulverization and breakage, further extending the adsorbent's service life; daily maintenance only requires regular maintenance of the front-end filter to reduce impurities entering the adsorption tower.
Supported. The PLC explosion-proof control cabinet is equipped with a Modbus-RTU communication interface, which can upload pressure, temperature, dew point, equipment alarms, and operating status to the oilfield host computer system; it also has a passive pulse signal remote start/stop interface to enable remote start/stop of the equipment. ⚠Note: Remote is only for monitoring and start/stop. After a major fault interlock shutdown, it is recommended that on-site personnel troubleshoot and confirm the root cause before resuming operation to ensure site safety.
The equipment is designed for an ambient temperature of -39°C to 47°C, and the hardware itself can withstand extreme cold field environments. The cold box uses Armstrong foam flame-retardant insulation material to reduce cooling loss; however, on site, heat tracing and insulation for external water pipes and drain lines of the skid must be done to prevent freezing and blockage of drain lines; the control system and motor meet dⅡBT4 explosion-proof requirements; under low-temperature conditions, it is recommended to focus on whether the regeneration heating temperature meets the standard, regularly check the filter drain to avoid freezing of liquid media, and ensure continuous operation of the entire unit.