Natural Gas Dehydration Unit

20

Get a Quick Quote >

Daily capacity of 144,000 cubic meters natural gas dehydration unit, dew point below -60°C, fully automatic control, molecular sieve adsorption dehydration unit. Overview

This YNG7-6000-0.7~1.2-AM natural gas dehydration unit launched by Zhejiang Yipu Energy Technology Co., Ltd. adopts a dual-tower molecular sieve adsorption process and is specially designed for deep dehydration of natural gas. The unit has a processing capacity of 6000Nm³/h@1.2MPa, an outlet dew point of ≤-60℃@0.1MPa, a working pressure of 0.7~1.2MPa, a design pressure of 1.6MPa, and a equipment pressure drop of ≤50kPa. The dual towers operate alternately to achieve continuous gas supply, and isobaric semi-open countercurrent regeneration reduces natural gas loss. The regeneration temperature is 150~180℃, and the regeneration cycle is adjustable at ≤10h. The whole unit has a skid-mounted structure and PLC automatic control, and is equipped with an explosion-proof booster, electric heater, cooling fan, and multiple over-temperature protections. The explosion-proof grade is ExdIBT4, suitable for old machine matching in Xinjiang projects and various natural gas deep dehydration scenarios.

Professional Daily capacity of 144,000 cubic meters natural gas dehydration unit, dew point below -60°C, fully automatic control, molecular sieve adsorption dehydration unit. Company

17+
years of professional field experience
6+
product R&D experience
9+
intellectual property
20+
industry application cases

Deeply engaged in customized solutions for the natural gas dehydration industry

Industry Pain Points

Water content in natural gas causes pipeline ice blockage and corrosion
Water content in natural gas causes pipeline ice blockage and corrosion
Moisture condenses when cooled to form hydrates
Blocking valves and pipelines, and combining with acid gases to accelerate pipe wall corrosion.
Replacing the entire unit during old equipment retrofit costs too much
Replacing the entire unit during old equipment retrofit costs too much
Aging of existing equipment leads to unstable dew point
Full unit replacement requires large investment, and shutdown construction affects production progress.
Regeneration venting causes relatively high natural gas loss
Regeneration venting causes relatively high natural gas loss
Conventional pressure-reduction regeneration requires pressure relief and venting
Natural gas loss is significant, and operating costs remain high
Molecular sieve replacement requires pipeline disassembly, which is time-consuming and labor-intensive
Molecular sieve replacement requires pipeline disassembly, which is time-consuming and labor-intensive
Replacing adsorbent in traditional adsorption towers requires pipeline disassembly
Long downtime and low maintenance efficiency.

Solutions

ProblemSolutions
Excessive water content in natural gas causes pipeline ice blockage and corrosionAdopts dual-tower molecular sieve adsorption dehydration, outlet dew point ≤-60℃@0.1MPa, controlling moisture from the source
Replacing the entire unit during old equipment retrofit costs too muchWhole-unit skid-mounted structure, all pipe openings and cables connected to the skid edge, adapting to existing sites and reducing modification construction costs
Downstream gas supply pressure fluctuation during dual-tower switchingPLC automatically controls valve switching timing, combined with flat diffusion structure, output gas is stable without pressure fluctuation
Large natural gas venting loss during regeneration processIsobaric semi-open countercurrent regeneration, regeneration pressure is approximately working pressure, high-humidity gas is cooled and separated then natural gas is reused
Unstable molecular sieve regeneration temperature controlHeater triple over-temperature protection, automatic power-off when temperature is too high, automatic power-on when temperature drops, maintaining 150~180℃
Inlet gas carrying free water or heavy hydrocarbons contaminates molecular sievePre-separation filter removes free oil, water and large particle impurities, protecting adsorbent and subsequent equipment
Molecular sieve replacement requires pipeline disassembly, time-consuming and labor-intensiveAdsorption tower is equipped with dedicated loading and unloading ports, molecular sieve can be replaced without disassembling pipelines
Equipment operation is limited in Xinjiang winter low-temperature environmentElectric heating regeneration is not affected by ambient temperature, pipelines can be equipped with insulation layers, explosion-proof rating ExdIBT4 adapts to the site
On-site operators have heavy inspection workloadPLC automatic control, automatic valve switching, regeneration heating and cooling proceed automatically without manual intervention
Equipment faults cannot be discovered and handled in timeEquipped with short-circuit and overload protection; automatically shuts down or stops regeneration in case of system abnormality; touch screen displays operating status

Core Advantages

deep dehydration

Dew point down to minus 60 degrees

Meets strict requirements for liquefaction and pipeline transmission

deep dehydration

continuous gas supply

Dual-tower alternating automatic switching operation

Stable output without pressure fluctuations

continuous gas supply

Energy-saving and gas-saving

Isobaric regeneration reduces venting losses

Regeneration gas returned to the system after cooling

Energy-saving and gas-saving

safe and reliable

Triple over-temperature protection with automatic power-off

explosion-proof rating meets on-site requirements

safe and reliable

Technical Principle

selective adsorption by molecular sieve

utilizes the selective adsorption of polar water molecules by the uniform micropores of the molecular sieve

retains moisture in natural gas under low temperature and high pressure

selective adsorption by molecular sieve

Dual-tower alternating continuous operation

single-tower regeneration and desorption

Automatic valve switching, achieves uninterrupted continuous gas supply

Dual-tower alternating continuous operation

isobaric countercurrent heating regeneration

the regeneration gas is heated and then introduced countercurrently into the tower

causing the molecular sieve to desorb moisture, stable pressure, low gas loss

isobaric countercurrent heating regeneration

cooling, separation and recycling

the high-humidity regeneration gas is condensed and separated by a cooler

liquid water is discharged, natural gas is returned to the front end of the system

cooling, separation and recycling

Technical Strength

industry-university-research collaborative R&D

industry-university-research collaborative R&D

continuous investment in adsorption materials,automation control,heating system optimization and other directions,。

directly applied to product control logic and operational reliability design.
Industry-standard manufacturing

Industry-standard manufacturing

and TSG 21 "Supervision Regulation on Safety Technology for Stationary Pressure Vessels" for design,manufacturing and inspection,to ensure equipment compliance and reliability.
Three-System Certification

Three-System Certification

ISO45001 Occupational Health and Safety Management System three-system integrated certification,ensuring product quality and production standards at the system level.
Verified by Renowned Customers

Verified by Renowned Customers

CSIC 711 Institute,Zhejiang Energy Group and other enterprises,products exported to Myanmar,Uzbekistan,Indonesia and many other countries.
Customized Service Capability

Customized Service Capability

Adaptable from retrofitting existing machines to new construction projects,meeting the diverse engineering needs of deep natural gas dehydration.

Process Flow

The working process of the Yipu YNG7-6000-0.7~1.2-AM natural gas dehydration unit can be summarized by four key words: "filtration - adsorption - regeneration - cooling".

Inlet gas and pretreatment section. Raw natural gas enters the unit from the gas inlet and first passes through a separation filter to remove free oil and water and larger particulate impurities. This step is critical -- if liquid water or heavy hydrocarbons enter the adsorption tower, they will directly contaminate the molecular sieve bed and cause the dehydration effect to decay rapidly. Engineering practice shows that when the heavy hydrocarbon content in the inlet gas composition is too high, an oil film is easily formed on the surface of the molecular sieve, and isobaric regeneration cannot effectively remove it, ultimately causing dehydration failure.

Adsorption and drying section. The pretreated natural gas enters Tower A or Tower B (depending on the current working cycle) and passes upward through the molecular sieve bed. Molecular sieve is a kind of aluminosilicate crystal with a uniform micropore structure, and its pore diameter is comparable to the diameter of water molecules. Under low-temperature and high-pressure conditions, it selectively adsorbs water molecules through van der Waals forces. The water molecules in the natural gas are retained in the molecular sieve channels, and the dried gas is discharged from the top of the tower, then deeply purified through a dust filter, and finally output from the gas outlet.

Regeneration and desorption section. When the molecular sieve in Tower A approaches saturation in water adsorption, the system automatically switches to the regeneration process. A small amount of natural gas is pressurized by a booster and enters the heater. After being heated to the set temperature, it is introduced in reverse from the dry gas outlet of the regeneration tower to heat the molecular sieve bed in countercurrent. The high-temperature gas flow causes the water molecules in the molecular sieve channels to desorb and be carried out of the tower. The regeneration temperature is usually controlled in the range of 150~180°C. Too high a temperature may affect the service life of the molecular sieve, while too low a temperature will result in incomplete desorption.

Cooling and separation section. The high-temperature, high-humidity natural gas coming out of the regeneration tower enters the cooler, where water vapor condenses into liquid water and is discharged through the gas-liquid separator. The separated natural gas returns to the front end of the system for recycling. The characteristic of this "isobaric semi-open countercurrent regeneration" process is that the regeneration process does not require completely releasing the pressure in the tower, avoiding the natural gas loss and pressure fluctuations caused by conventional pressure-reduction regeneration.

The entire process is automatically controlled by PLC, with the two towers working alternately. When one tower is adsorbing, the other is regenerating or on standby, achieving continuous gas supply. The working cycle can be set within the range of 12~24 hours, and the regeneration cycle is ≤10 hours and adjustable.

Product Parameters

ParameterItem Specification
EquipmentModel YNG7-6000-0.7~1.2-AM
WorkingMedium Natural Gas
ProcessingCapacity 6000Nm³/h@1.2MPa
WorkingPressure 0.7~1.2MPa
DesignPressure 1.6MPa
InletTemperature ≤25℃
OutletTemperature Ambient Temperature+15℃
InletWater Content -13℃@0.8MPa
OutletDew Point ≤-60℃@0.1MPa
DehydrationMethod Adsorption Dehydration (Molecular Sieve)
WorkingMode Dual-tower alternating, continuous operation
RegenerationMode Isobaric semi-open countercurrent regeneration
RegenerationTemperature 150~180℃
CoolingMethod Air Cooling
EquipmentPressure Drop ≤50kPa
WorkingCycle 12h~24h
RegenerationCycle ≤10h (adjustable)
Inlet/OutletPipe Diameter Flange WN150(B)-25RF
Explosion-proofGrade ExdIBT4
EquipmentPower ≤51kW
PowerSupply AC380V/50Hz
StructuralForm Complete Skid-mounted Unit
OverallDimensions Approx. 4500×2300×2830mm

Office Environment

1
1
2
3
4
5
6
7
8
9
10
11
12
14
16
17
18
19
20
1

Partner Clients

Some Customers

1
1
2
2
3
3
4
4
5
5
6
6
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
7
7
8
8
9
9
10
10
11
11
12
12

FAQ

Send Inquiry