High-efficiency explosion-proof biogas refrigerated dryer; Yipu-brand biogas refrigerated dryer helps biogas power generation and purification
Safe and Worry-Free
In the process of biogas energy utilization, moisture removal is a key step to ensure stable equipment operation and gas quality. However, traditional drying equipment often suffers from low processing efficiency, high pressure drop, and insufficient explosion-proof performance. Especially for biogas systems under micro-negative pressure conditions, a slight oversight may lead to safety hazards or equipment failure. To address these pain points, Yipu Energy has launched the [Biogas Refrigerated Dryer] series, including the [Explosion-Proof Biogas Refrigerated Dryer], [Biogas Refrigeration Dryer], [Biogas Power Generation Refrigerated Dryer], [Biogas Purification Refrigerated Dryer], [Biogas Cleaning Refrigerated Dryer], and [Biogas Dryer], tailored specifically for biogas operating conditions to thoroughly solve the challenge of biogas dehydration.

I. Market Pain Points
As a renewable energy source, biogas often contains saturated water vapor. During subsequent compression, transportation, or combustion, condensed water vapor forms liquid water, causing pipeline corrosion, valve blockage, unstable combustion, and even explosion risks. Traditional refrigerated dryers have large pressure drops and unstable dew points under micro-negative pressure and high humidity conditions, and lack explosion-proof design, making them unsafe for biogas power generation, purification, and other scenarios. Yipu [Biogas Refrigerated Dryer] addresses these pain points by adopting corrosion-resistant 304 stainless steel heat exchangers and explosion-proof electrical control systems, ensuring stable operation under micro-negative pressure and sulfur-containing environments, with an outlet temperature of 10-15°C and a relative humidity of ≤50% after downstream pressurization, meeting downstream equipment requirements.

In addition, hydrogen sulfide (H₂S) in biogas is highly corrosive to metal materials, especially in the presence of water, which accelerates equipment damage. If traditional refrigerated dryers use carbon steel or copper, corrosion will lead to leakage and performance degradation. Yipu uses 304 stainless steel as a comprehensive replacement, fundamentally solving the corrosion problem. Under micro-negative pressure conditions, ordinary drying equipment often cannot operate normally due to excessive resistance. Yipu optimizes the flow channel design and adopts low-resistance heat exchangers to control the pressure drop within 0.5kPa, ensuring system stability.

II. System Process
After primary pretreatment (desulfurization and dust removal), the residual biogas enters the inlet of the [Biogas Refrigeration Dryer] under micro-negative pressure. It first passes through the pre-cooling section, where it exchanges heat with the outlet cold gas for initial cooling, then enters the evaporator and is deeply cooled to 10-15°C by the refrigeration system, condensing water vapor into liquid water. The gas-liquid mixture enters the built-in stainless steel gas-water separator, where liquid water and solid particles are removed through velocity reduction and collision coalescence, and discharged through an automatic drain valve. The dried gas is reheated in the reheating section and output to downstream pressurization or usage stages. The entire process is compact, with a pressure drop of ≤0.5kPa.
Specifically, the pre-cooler adopts a shell-and-tube structure, using the cooling capacity of the outlet cold gas to pre-cool the inlet hot humid gas, recovering cooling capacity and reducing the refrigeration load. The evaporator uses high-efficiency finned tubes, with refrigerant evaporating and absorbing heat inside the tubes while biogas flows between the fins, achieving counter-flow heat exchange to rapidly cool the biogas below the dew point. The gas-water separator combines cyclone separation with wire mesh demisting, achieving a separation efficiency of up to 99.9%. The automatic drain valve is float-type or solenoid-type, automatically draining water based on liquid level, and can work reliably even under micro-negative pressure. The reheater uses the outlet cold gas for reheating to prevent pipeline condensation.
III. Working Principle
Yipu [Explosion-Proof Biogas Refrigerated Dryer] adopts a vapor compression refrigeration cycle. Refrigerant R22 is compressed into high-temperature high-pressure gas in the compressor, condensed into high-pressure liquid in the air-cooled condenser, throttled through the expansion valve to low-temperature low-pressure gas-liquid mixture, and enters the evaporator to absorb heat from the biogas, cooling it below the dew point. The evaporator uses a high-efficiency finned tube heat exchange structure made of corrosion-resistant 304 stainless steel. The refrigeration system is equipped with a hot gas bypass valve that automatically adjusts cooling capacity based on load changes to ensure stable outlet temperature. The explosion-proof electrical control cabinet meets EX DIIBT4 rating, and the temperature transmitter and pressure controller are both explosion-proof types.
The core of the compressor refrigeration cycle lies in the state changes of the refrigerant. The high-temperature high-pressure superheated vapor discharged from the compressor exchanges heat with ambient air in the condenser and condenses into high-pressure liquid. After throttling through the expansion valve, it becomes a low-temperature low-pressure gas-liquid mixture, which evaporates and absorbs heat in the evaporator, cooling the biogas. The hot gas bypass valve draws a portion of high-temperature gas from the compressor discharge pipe directly into the evaporator inlet, mixing with the throttled gas-liquid to raise the evaporator inlet temperature, preventing biogas freezing due to excessively low evaporation temperature while adjusting cooling capacity. The explosion-proof electrical system includes flameproof junction boxes, intrinsically safe sensors, and isolated safety barriers, ensuring precise control while isolating all electrical sparks.
IV. Core Advantages
1. Explosion-proof safety: The entire unit has an explosion-proof rating of EX DIIBT4, suitable for flammable and explosive gases such as biogas, ensuring personal and equipment safety. All electrical components are explosion-proof types, and the enclosure is equipped with positive pressure ventilation or flameproof housing to prevent any ignition source from contacting biogas.
2. Low resistance and high efficiency: Pressure drop under micro-negative pressure conditions is ≤0.5kPa, meeting system resistance requirements; the evaporator is made of stainless steel, offering corrosion resistance and long service life. Optimized through CFD flow field simulation, the flow channels have no dead zones and high heat exchange efficiency.
3. Intelligent control: Standard inlet temperature automatic control shuts down automatically when below the set value to prevent ice blockage; remote start/stop, fault alarms, and temperature analog signal upload are available. Equipped with a touch screen for real-time display of operating parameters, and supports communication interfaces for connection to DCS systems.
4. Quality components: Danfoss compressors and refrigeration valves, Sporlan hot gas bypass valves, stable and reliable. All valves undergo strict testing to ensure long-term operation in corrosive environments.
5. Flexible installation: Enclosure-type outdoor design, installed on level ground without foundation, with a recommended rain cover on top, adapting to various sites. The base is equipped with leveling bolts and vibration damping pads for low vibration and low noise.
V. Technical Strength
Yipu Energy has been deeply engaged in the biogas treatment field for many years and holds multiple patented technologies. This equipment strictly complies with the GB3836 series explosion-proof standards and JB/T10526 refrigerated dryer standards. Core components such as evaporators and separators are independently designed and manufactured, and through precise heat exchange calculations and flow field simulations, pressure drop is minimized while ensuring dewatering effectiveness. The refrigeration system is optimally matched, with precise hot gas bypass adjustment to adapt to year-round operating condition changes. Strict explosion-proof performance tests and refrigerated dryer performance tests are conducted before delivery to ensure the stability and reliability of each [Biogas Cleaning Refrigerated Dryer].
The company has a professional R&D team, including refrigeration engineers, explosion-proof experts, and automation engineers, who can customize processing capacity, outlet dew point, explosion-proof rating, and other parameters according to users' special requirements. The production workshop is equipped with helium leak detection equipment, performance test benches, and explosion-proof test chambers. All products undergo 72-hour continuous operation testing before delivery to ensure no leakage and no failure. In addition, Yipu provides comprehensive technical support and after-sales service, including on-site installation guidance, commissioning, training, and regular inspections.
VI. Product Introduction
Featured model: YPAD-1200Nm3/h-EX [Explosion-Proof Biogas Refrigerated Dryer], processing capacity 1200Nm3/h (including 10% margin), air-cooled heat dissipation, cooling capacity 61kW, total power ≤25kW. Inlet/outlet diameter DN200, 304 stainless steel flanges. The evaporator and all gas-contact parts are made of 304 stainless steel. The unit weighs 1600kg, with protection rating ≥IP55. This [Biogas Dryer] is particularly suitable for biogas power generation, purification, cleaning, and other applications requiring deep dehydration and explosion-proof requirements.
The product features a modular design, with the compressor, condenser, evaporator, separator, and electrical control cabinet integrated on the same steel base frame for integrated transportation and installation. The enclosure is coated with weather-resistant steel plate, providing rain and sun protection. An optional rain canopy can be configured on top, with drain holes at the bottom. All piping is stainless steel, with explosion-proof sealed connectors. The electrical control box is flameproof, with rail-mounted components for easy maintenance.
VII. Technical Specifications
- Processing gas volume: 1200 Nm³/h (standard conditions, 10% margin)
- Inlet temperature: ≤40°C
- Outlet temperature: 10~15°C
- Working pressure: Micro-negative pressure (-5~0 kPa)
- Controlled pressure drop: ≤0.5 kPa
- Refrigerant: R22
- Cooling method: Air-cooled
- Power supply: 380V/3PH/50Hz
- Refrigeration compressor power: 20HP (approx. 15kW)
- Total power: ≤25kW
- Explosion-proof rating: EX DIIBT4
- Evaporator material: 304 stainless steel
- Separator material: 304 stainless steel
- Installation method: Outdoor level ground, rain canopy recommended
- Dimensions: Approx. 2500×1500×2000 mm